Skip to content

Kingspan STG wind/rain detector system WRZ-40M-4G set with wind-rain detector

Original price €1.265,57 - Original price €1.265,57
Original price
€1.265,57
€1.265,57 - €1.265,57
Current price €1.265,57

Produktübersicht

Ventilation center for controlling max. 40 x 230 V AC ventilation drives (e.g. type M3) with a total current consumption of 8 A, distributed over 4 motor groups. There are connection options for ventilation buttons as well as wind and rain detectors.

Wind/rain detection systems WRZ-40M-4G

Special features:

  • Connection for up to two wind/rain detectors WRM/2 24V or features for up to two rain detectors RM/2 24V
  • Connection for 230 V and 24 V ventilation buttons
  • Automatic closing of windows, flaps and skylights in conjunction with 230 V AC drives after a wind/rain report
  • Time-dependent forwarding of the wind/rain signal, configurable via DIP switches
  • Cascading of several WRZs (maximum 4 pieces)
  • Status messages via visual display
  • Display of the activation of the respective detectors, separated according to wind and rain

Technical data:

Mains supply voltage: 230 V AC, (±10%), separately fused
Power consumption: max. 1860 W
Power consumption (standby): depends on the connected components
Connection terminal: spring terminal, max. 2.5 mm²

Output drives
Voltage: 230 V AC nominal (±10%)
Rated current: 2 A per drive group
Automatic activation: duration or 2 second pulse (for solenoid valves), adjustable
Connection terminal: spring terminal, max. 2.5 mm²
Fuse: T 3.15AH

Wind/rain detector output
Voltage: 24 V nominal
Current: max. 500 mA (total current for 2 wind/rain detectors)
Connection terminal: spring terminal, max. 1.5 mm²
Max. quantity: 2 pieces (type WRM/2 or RM/2)
Fuse: None

Dimensions: (H x W x D) 175 x 250 x 75 mm
Weight: approx. 1kg
Nominal temperature 20 °C
Ambient temperature –5 °C to +40

Wind-rain detector WRM/2 24V

For connection to 24 V DC RWA and ventilation panels and 230 V AC wind and rain detection panels. With built-in evaluation electronics for wind and rain reports. Outside temperature-dependent, heated sensor surface.
Forwarding of the wind pulses via a separate output possible.

Technical data:

  • Supply voltage: 20-30V DC or 20-28V AC
  • Current consumption: max. 110 mA
  • Current consumption standby: approx. 33 mA
  • Output potential-free changeover contact: max. 30 V / 1 A
  • Connections: max. 2.5 mm²
  • Ambient temperature range: -20°C to +60°C
  • Delivery includes mounting bracket.