Produktübersicht
When there is no power, the drive opens the door with the spring. Opening and closing speed can be individually adjusted. Hydraulic final blow that accelerates the door shortly before it is closed. Inverse function opens the doors using spring force and closes them using a motor. The vestibule function regulates the opening and closing of two doors one behind the other (lock). Obstacle detection detects an obstacle when touched and stops the opening or closing process. Automatic reversing detects an obstacle and returns to the opening position. The Push & Go function triggers the automatic drive system after light manual pressure on the door leaf. Drive can be used with roller rail or rod. Integrated back check, slows down heavily opened doors. Areas of application: RWA supply air opening systems. Doors along escape and rescue routes. Single and double leaf right and left hinged doors. Double-action doors with a hinge distance of up to 2800 mm, a leaf width of 1400 mm or a weight of 250 kg. Minimum hinge distance 1500 mm, minimum width of the inactive leaf 400 mm. Interior and exterior doors with high traffic. Symmetrical and asymmetrical door divisions possible. Head assembly.