Skip to content

Produktübersicht

Infinitely adjustable closing force from EN3-6. Opening and closing speed can be individually adjusted. Mechanical final strike in de-energized operation and electrical final strike in regular operation, which accelerates the door shortly before the closed position. Mechanical and electrical closing sequence control keeps the active leaf in waiting position until the passive leaf is closed. Low-energy function opens and closes the door at reduced travel speed, thus meeting the highest safety requirements. Servo function for motor support when opening the door manually. The vestibule function regulates the opening and closing of two doors one behind the other (lock). Obstacle detection detects an obstacle when touched and stops the opening or closing process. Automatic reversing detects an obstacle and returns to the opening position. The Push & Go function triggers the automatic drive system after light manual pressure on the door leaf. Drive can be used with roller rail or rod. Areas of application: fire and smoke protection doors. Double-leaf right and left hinged doors. Double-action doors with a hinge distance of up to 2800 mm, a leaf width of 1400 mm or a weight of 230 kg. Minimum band spacing 1500 mm, minimum sash width 750 mm. Interior and exterior doors that must close in the correct order even without power. Head assembly on hinge and opposite hinge side.