Skip to content

Produktübersicht

Application: Ventilation in solo operation
Integrated load switch-off electronics S2 in OPEN/CLOSE direction
KS2 S2 24V DC R/L

TECHNICAL DATA
UN rated voltage 24V DC (19 V ... 28 V)
IN rated current 0.5 A
IA shutdown current 0.7 A
PN rated consumption 12 W
DC duty cycle 5 cycles (ED 30% - ON: 3 min. / OFF: 7 min.)
Protection class IP 32
Ambient temperature -5 °C ... +60 °C
FZ tensile force max. 200 N
FH locking force 1,800 N (depending on fastening)
Stainless steel chain, without protruding rivet heads.
Easy connection to a wing trestle.
Small bending radii enable large opening angles with low sash heights.
Connection cable halogen-free, gray 3 x 0.5 mm², ~ 3 m
v Speed ​​10.0 mm/s 10.0 mm/s
s stroke 50 – 800 mm
L Total length see ordering data
Emission sound pressure level 70 dB (A)