Ventilation control center for controlling 24 V DC drives with a current consumption of up to 8 A. There are connection options for ventilation buttons, wind/rain detectors and sensors for ventilation control.
- Built-in standard ventilation control functions
- Features Visual display for errors and operating messages
- Cascading of several iVent/2 8A possible with operation via one or more ventilation buttons
- Functions for interacting with shading 1)
- Internal function monitoring with error signaling
- Incl. service port interface for configuring advanced functions via the PC service port software such as:
- Time-dependent stroke limitation 1)
- Automatic ventilation via temperature 1)
- Automatic closing after a set time 1)
- Manual ventilation in pulse or momentary operation (dead man) 1)
- Change in the properties for the operating displays 1)
- Adjustable pause time when polarity reversal of the drive voltage 1)
- Superior closing function in the event of rain
1) Functionality only possible via a notebook/PC with installed service port software and connection cable.
Areas of application:
- Natural ventilation and ventilation
Material:
- Plastic housing for surface mounting,
- Color gray
Technical data:
Mains supply voltage: 230 V AC, (±10%), separately fusedPower consumption: approx. 260 W
Power consumption (standby): approx. 7 W
Connection terminal: spring terminal, max. 2.5 mm²
Voltage: 27.5V (nominal)
Permissible ripple of rated voltage: 0.3 Vpp
Current (nominal): 8 A at ED 30 (10 min)
Current (short-term): 10 A for 5 s
Opening/closing process: polarity reversal of the voltage
Dimensions (H x W x D): 250 x 175 x 75 mm
Weight: approx. 1.6 kg
Nominal temperature: 20°C
Ambient temperature: 0°C to +50°C
Protection class: IP 54
You may also like
Kingspan STG ballast VNT 8A/2
STG BeikirchFor operating 24 V drives on a 230 V AC mains voltage Advantages/Features: Control via ON/OFF button operation via external 230 V AC...
View full detailsKingspan STG ballast VNT 2.5A
STG BeikirchFor operating 24 V drives on a 230 V AC mains voltage Advantages/Features: Control via ON/OFF button operation via external 230 V AC...
View full detailsKingspan STG wind and rain detection center WRZ 40M/4G without “manual/automatic” switch
STG BeikirchVentilation center for controlling max. 40 x 230 V AC ventilation drives (e.g. type M3) with a total current consumption of 8 A, distributed ove...
View full detailsKingspan STG wind and rain detection center WRZ 40M/4G without “manual/automatic” switch
STG BeikirchVentilation center for controlling max. 40 x 230 V AC ventilation drives (e.g. type M3) with a total current consumption of 8 A, distributed ove...
View full detailsKingspan STG wind/rain detector system WRZ-40M-4G set with wind-rain detector
STG BeikirchVentilation center for controlling max. 40 x 230 V AC ventilation drives (e.g. type M3) with a total current consumption of 8 A, distributed over ...
View full details