Skip to content

Produktübersicht

Ventilation control center for controlling 24 V DC drives with a current consumption of up to 8 A. There are connection options for ventilation buttons, wind/rain detectors and sensors for ventilation control.

Advantages/Features:
  • Built-in standard ventilation control functions
  • Features Visual display for errors and operating messages
  • Cascading of several iVent/2 8A possible with operation via one or more ventilation buttons
  • Functions for interacting with shading 1)
  • Internal function monitoring with error signaling
  • Incl. service port interface for configuring advanced functions via the PC service port software such as:
    • Time-dependent stroke limitation 1)
    • Automatic ventilation via temperature 1)
    • Automatic closing after a set time 1)
    • Manual ventilation in pulse or momentary operation (dead man) 1)
    • Change in the properties for the operating displays 1)
    • Adjustable pause time when polarity reversal of the drive voltage 1)
  • Superior closing function in the event of rain

1) Functionality only possible via a notebook/PC with installed service port software and connection cable.

Areas of application:

  • Natural ventilation and ventilation

Material:

  •  Plastic housing for surface mounting,
  • Color gray

Technical data:

Mains supply voltage: 230 V AC, (±10%), separately fused
Power consumption: approx. 260 W
Power consumption (standby): approx. 7 W
Connection terminal: spring terminal, max. 2.5 mm²
Voltage: 27.5V (nominal)
Permissible ripple of rated voltage: 0.3 Vpp
Current (nominal): 8 A at ED 30 (10 min)
Current (short-term): 10 A for 5 s
Opening/closing process: polarity reversal of the voltage
Dimensions (H x W x D): 250 x 175 x 75 mm
Weight: approx. 1.6 kg
Nominal temperature: 20°C
Ambient temperature: 0°C to +50°C
Protection class: IP 54