Technical description:
Ventilation smoke switch system for smoke monitoring in potentially explosive areas
Areas of Zone 1 and Zone 2. This
System, consisting of ventilation smoke switch and Ex connection box, is pre-wired for quick and easy
Installation on the ventilation duct.
The system is assembled by
outside and can be used on both channels
both round and square cross-sections. The attachment can
with screws or tension straps
ventilation duct.
The evaluation electronics of the smoke switch monitors the smoke measuring part
for contamination and disruption. The
Operating states: operation, contamination,
Fault and alarm become visual
displayed and are visible from the outside.
Thanks to the automatic alarm threshold tracking and the intelligent
Evaluation electronics is a constant response and therefore
safe operation and increased
Lifespan guaranteed.
Optionally, the individual operating states can be controlled via the integrated RS bus
System read and sent to higher-level
positions are forwarded.
Thanks to the maintenance-friendly structure
The annual revision can be carried out without tools
take place.
Performance features:
- Atex approved for Zone 1
and Zone 2
- intrinsically safe
- Operation 24 V DC
- Easy construction
- Screw and/or strap assembly
possible
- For channels with round and square ones
Cross sections
- Vibration decoupling through moss rubber
slices
- Tool-free testing, maintenance and
cleaning
- Easy removal of the inlet pipe
maintenance
- Inlet pipe can be optimally adjusted in length
- Can be used up to 20 m/s
- Optical smoke detection after
Scattered light principle
- Visual display for operation,
pollution,
Fault and alarm visible from outside
- Potential-free changer, opens at
Alarm and disturbance
- Measuring chamber monitoring
- Standard installation, cable without
Functional maintenance
- RS bus for connecting the editing
point for the connection to the
Building control technology
- Yearly maintenance
- 5 year guarantee
- The LRS guarantee conditions apply
(www.hekatron.de)
Nominal data system:
Rated input voltage 24 V DC
Current consumption max. 12 mA
Smoke detection according to EN 54, part 7
Relative humidity up to 95% without
dew
Switching capacity relay 30 V AC/DC 1 A
Protection class IP 54
Operating ambient temperature
-20°C to +70°C
Duct installation depth 140 to 345 mm
Air flow 1 to 20 m/s
Dimensions LxWxH 520 x 135 x 105
Weight 2740 g (including smoke switch)
Manufacturer: Hekatron Vertriebs GmbH
Type: LRS 04 Ex